Making the Case
Success with Using Fluxtrol
|
|
|
| Application: |
Crank Shaft Hardening Single Journal Lawn Mower Engine |
| Original Concentrator: |
No Concentrator on Original Coil |
| Problem / Failure Mode: |
Pattern Difficult to Achieve Bottle Neck for Production Quality of Case Depth Poor Inconsistent Case Depths Product to Product Long Time for Change Over's Up to 1 Day Short Coil Life 10,000 to 18,000 Shots |
| Power Supply: |
100 kW 100kHz |
| Problem / Solution: |
Fluxtrol Concentrator Used as Side Shields Removable Contacts Designed into Head Coil Design Optimized via Computer |
| Fluxtrol Advantage: | Coil Life Typically 75,000+ Shots First Time Pass-Off Every Time So Far |