Making the Case
Success with Using Fluxtrol
|
|
|
| Application: |
Case Harden S-Cam and Shaft |
| Original Concentrator: |
None |
| Problem / Failure Mode: |
Extended Cycle Times / Loss of Pattern Control |
| Power Supply: |
150 kW (135 kW in use), 3–10 kHz (7 kHz in use) |
| Problem / Solution: |
Customer not satisfied with cycle times Customer experiencing loss of pattern control Coil and application reviewed for pattern and time Optimized coil design via computer simulation New coil design utilizes Fluxtrol A material Tests meet spec and coil returned to production |
| Fluxtrol Advantage: | Cycle Time Reduced 46% with Pattern Improvement! |

© 2008 Fluxtrol, Inc.
www.fluxtrol.com