Application: Case Harden S-Cam and Shaft
-
Original Concentrator: None
-
Problem / Failure Mode:
Extended Cycle Times / Loss of Pattern Control
-
Power Supply: 150 kW (135 kW in use), 3–10 kHz (7 kHz in use)
-
Problem / Solution:
- Customer not satisfied with cycle times
- Fluxtrol given opportunity to replace laminations
- Coil and application reviewed for pattern and time
- Optimized coil design via computer simulation
- New coil design utilizes Fluxtrol A material
- Tests meet spec and coil returned to production
-
Fluxtrol Advantage: Cycle Time Reduced 46% with Pattern Improvement!