Application: Geared Tractor Hub / Simple O.D. Coil with Integral Quench
-
Original Concentrator: None
-
Problem / Failure Mode:
Long cycle times and poor heat pattern control
-
Power Supply: 50 kW (22 kW in use), 10 kHz
-
Problem / Solution:
- Customer not satisfied with cycle time
- Customer experiencing high scrap rates
- Application evaluated and Fluxtrol A selected
- No other changes were made other than adding Fluxtrol A
- Fluxtrol applied per supplied guidelines
- Tests meet spec and coil returned to production
-
Fluxtrol Advantage: Cycle Time Reduced 42%, Positive Control of Heat Pattern!